Milwaukee
Electro-Magnetic
Drills
CAT
40
&
CAT
50
TECHNIKS
12-PACK
SPECIALS
|
Buy
2 EZ-Lift
lifting magnets for $399! Save 8%
Click here 
|
Call
888-849-8034 to use PayPal
Send
an e-mail
For
models and sizes not appearing here or not listed on Industry
Depot...Request a quote
Warranty
& Return Policy
Tel.
Toll Free 888-849-8034
|
|
Instrument
calibration and simulation instruments! |
VC-04 Voltage / Current Simulator
Combines voltage and current source and read functions into one instrument
- ±0.05% accuracy
- Automatic calibration
- User selectable auto
power-off
- Includes test leads,
soft carrying case and batteries
SPECIFICATIONS: output function Voltage Range:
10V Output Range: 0.00 to 11.000V Resolution:
1mV Accuracy: ±0.05% setting Current Range:
20mA Output Range: 0.000 to 22.000mA Resolution:
0.001mA Accuracy: ±0.05% setting + 4µA
Analogue Transducer: -20mA Output Range: 0.000
to -22.000mA Resolution: 0.001mA Accuracy: ±0.05%
setting + 4µA Loop Power: 24V Accuracy: ±10%
Power Supply: Single 9V alkaline battery Battery
Life: Approx. 20 hours Ambient Conditions: -10
to 55°C; ? 80% RH Dimensions: 200 x 100 x 40mm
w/ holster Weight: 550g w/ holster.
Part No.VC04
Add
to cart 
Industry Depot is
an
|
CC-421
Voltage / Current Calibrator
Sources and measures current and voltage
- 1/2" (13mm) LCD
display
- Includes test leads
SPECIFICATIONS: Current Source: 0 to 24 mA (2
ranges) Current Measure: 0 to 24 mA (2 ranges)
Voltage Source: -199.9 to +199.9 mV DC
Dimensions: 7.3 x 3 x 1.5" (185 x 78 x
38mm) Weight: 9.4 oz (265g)
CC-422
Current Calibrator
- 1/2" (13 mm) LCD
display
- Includes test leads
SPECIFICATIONS: Range: 0 to 19.99 mA; 0 to
24.0 mA Resolution: 0.01 mA; 0.1 mA Sampling
Time: 0.4 second Dimensions: 7.3 x 3 x
1.5" (185 x 78 x 38mm) Weight: 9.4 oz
(265g)
Part No.CC-421
Add
to cart 
Part No.CC-422
Add
to cart 
For
prices, click item "Add to
Cart" icon or call 888-849-8034
|
| VC-05
Loop Calibrator
mA sourcing, simulation and measurement to check loop voltage
- 0.02% accuracy
and 0.001% of span display
- Simulate mA and
% of span display
- Selectable step
or ramp outputs
- 24V loop power
supply
- Includes test
leads, soft carrying case &
batteries
SPECIFICATIONS: measurement function
Voltage Range: -0.200 to 28.000V
Resolution: 1mV Accuracy: ±0.02% rdg.
±2mV Current Range: -1.000 to 22.000mA
Resolution: 0.001 mA Accuracy: ±0.02%
rdg. ±4µA Loop Current Range: 0.000 to
22.000mA Resolution: 0.001 mA Accuracy:
±0.02% rdg. ±4µA Output function
Current Range: 0.000 to 22.000mA
Resolution: 0.001mA Accuracy: ±0.05% ±4µA
Loop Power Range: 24V Accuracy: ±10%
Power Supply: Single 9V battery Battery
Life: Approx. 12 hours
Dimensions/Weight: 200 x 100 x 40mm/550g
Part
No.VC05
Add
to cart 
For
prices, click item "Add to
Cart" icon or call 888-849-8034
|
VC-15
Voltage / Current Calibrator
6-digit LCD readout, auto calibration, auto power off
- Auto power off
- Includes test
leads, soft carrying case &
batteries
SPECIFICATIONS: measurement function
Voltage Range: 0.000 to 11.000V
Resolution: 1mV Accuracy: ±0.02% rdg.
±0.01% range Current Range: 0.000 to
22.000mA Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±0.01% range
Loop Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA Accuracy: ±0.02%
rdg. ±0.01% range Output function
Voltage Range: 0.000 to 11.000V
Resolution: 0.1mV Accuracy: ±0.02%
rdg. ±0.01% range Current Range:
0.000 to 22.000mA Resolution: 0.001 mA
Accuracy: ±0.05% ±0.01% range Loop
Power Range: 24V Accuracy: ±10% Power
Supply: Single 9V battery Battery
Life: Approx. 12 hours
Dimensions/Weight: 200 x 100 x
40mm/550g
Part No.
VC15
Add
to cart 
Part No.SW-U801-WIN
Add
to cart 
Part No.UPCB-02
Add
to cart 
Part No.CA-05A
Add
to cart 
|
| VC25
Process Calibrator
Multifunction calibrator can be used to test and calibrate almost any process
- Accurate to
0.02%
- Simulates
and reads 3 RTDs and 8 thermocouples
- Measures 2
or 3-wire RTDs
- Compatible
with 32 pressure modules from 2.5kPa
to 70MPa
- 24V loop
power supply
- Provides 25%
or 100% step output for DC current
either manually or automatically
- Large 2-line
LCD with whie LED backlight
- User
selectable auto power off
- Includes
test leads, soft carrying case and
batteries
Part No.VC25
P
Add
to cart  |
|
VC25
SPECIFICATIONS:
READ
DC Voltage Range: 50mV,
500mV, 5V, 50V
Accuracy: ±0.02% +10, ±0.02%
+2, ±0.02% +5,±0.03% +5.
DC Current Range: 50mA
Accuracy:
±0.02% +2.
Resistance Range: 500 Ohms,
5kOhms.
Accuracy: ±0.02% +0.1Ohms,
±0.02% +0.5Ohms.
Frequency Range: 100Hz,
1kHz, 10kHz Accuracy: ±2%
SOURCE
DC Voltage Range: 100mV, 1V,
10V. Accuracy:
±0.02% +10. DC
Current Range: 20mA.
Accuracy: ±0.02% +10.
Resistance
Range: 400Ohms, 4kOhms, 40kOhms.
Accuracy: ±0.02% +0.1Ohms,
±0.05% +1Ohms, ±0.1% +10Ohms.
Frequency Range: 100Hz,
1kHz, 10kHz, 100kHz.
Accuracy: ±2% |
| FUNCTION |
READ
RANGE |
ACC'Y |
SOURCE
RANGE |
ACC'Y |
| Type
R T/C |
-40/1760Cº |
+/-1.5Cº |
-40/1760Cº |
+/-1.2Cº |
| Type
S T/C |
-20/1760Cº |
+/-1.5Cº |
-20/1760Cº |
+/-1.5Cº |
| Type
KT/C |
-200/950Cº |
+/-0.8Cº |
-200/1370Cº |
+/-0.9Cº |
| Type
E T/C |
-200/500Cº |
+/-1.5Cº |
-200/1000Cº |
+/-0.5Cº |
| Type
J T/C |
-200/700Cº |
+/-0.7Cº |
-200/1200Cº |
+/-0.7Cº |
| Type
T T/C |
-200/400Cº |
+/-0.7Cº |
-200/400Cº |
+/-0.6Cº |
| Type
N T/C |
-200/1000Cº |
+/-0.9Cº |
-200/1300Cº |
+/-0.8Cº |
| Type
B T/C |
400/1800Cº |
+/-1.8Cº |
400/1800Cº |
+/-1.1Cº |
| Pt100
RTD |
-200/700Cº |
+/-0.8Cº |
-200/850Cº |
+/-0.8Cº |
| Pt
1000 RTD |
-200/630Cº |
+/-0.4Cº |
-200/630Cº |
+/-0.4Cº |
| Cu50 |
-50/150Cº |
+/-0.7Cº |
-50/150Cº |
+/-0.5Cº |
|
| CC-TEMPK
Type K Thermocouple Simulator
Checks the calibration of Type K meters or controllers
- Instantly
determine if your device needs
calibration or if a sensor needs
to be replaced
- Complete
with 9V battery, vinyl pouch
case and 60" calibration
cable terminated with
subminiature connector
SPECIFICATIONS:
Temperature Ranges: 32°F (0°C),
212°F (100°C), 932°F (500°C),
1832°F (1000°C) Accuracy: ±(0.25%
+ 1°F/°C) Power Supply: Single
9V battery Dimensions: 3.5 x 2.3
x 1" (89 x 58 x 25mm)
Weight: 10 oz (285g)
Part No.CC-TEMPK
Add
to cart 
For
prices, click item "Add to
Cart" icon or call 888-849-8034
|
VC01
Temperature Simulator
Temperature simulator that includes test leads, soft carrying case and batteries.
SPECIFICATIONS:
OUTPUT FUNCTION Voltage
Range/Resolution:-10.00 to
110.00mV/0.01mV; -100.00 to
1100.0mV/0.1mV Resistance
Range/Resolution: 0.0 to 400.0?/0.1?
Thermocouple Range/Resolution: R:
-40 to 1760°C/1°C; S: -20 to 1760°C/1°C;
B: 400 to 1800°C/1°C; E: -200.0 to
1000.0°C/0.1°C; K: -200.0 to
1370.0°C/0.1°C; J: -200.0 to
1200.0°C/0.1°C; T: -200.0 to 400.0°C/0.1°C;
N: -200.0 to 1300.0°C/0.1°C
Thermo-resistance Range/Resolution:
Pt100: -200.0 to 850.0°C/0.1°C;
Cu50: -50.0 to 150.0°C/0.1°C
Accuracy: ±0.05% setting value
Power Supply: Single 9V battery
Dimensions/Weight:: 200 x 100 x
40mm/550g
Part No.VC01
Add
to cart
|
| VC14
Temperature Calibrator
Automatic calibration with 6-digit LCD readout
- 6-digit
LCD readout
- ±0.02%
accuracy
- Automatic
calibration
- User
selectable auto power-off
- Includes
test leads, soft carrying case
and batteries
|
|
VC14
SPECIFICATIONS: |
| OUTPUT
FUNCTION: Voltage
Range/Resolution: -10.000 to
110.000mV/10µV; -0.10000 to
1.10000V/0.01mV |
| Resistance
Range/Resolution: 0.00 to
400.00?/00.1? |
| Thermocouple
Range/Resolution: R: -40 to
1760°C/1°C; S: -20 to 1760°C/1°C;
B: 400 to 1800°C/1°C; E:
-200.0 to 1000.0°C/ 0.1°C;
K: -200.0 to 1370.0°C/0.1°C;
J: -200.0 to 1200.0°C/0.1°C;
T: -200.0 to 400.0°C/0.1°C;
N: -200.0 to 1300.0°C/0.1°C |
| Thermo-resistance
Range/Resolution: Pt100:
-200.0 to 850.0°C/0.1°C;
Cu50: -50.0 to 150.0°C/0.1°C |
| MEASUREMENT
FUNCTION : Voltage
Range/Resolution: 0.00 to ±450.00mV/10µV
Resistance Range/Resolution:
0.00 to 450.00?/00.1? |
| Thermocouple
& Thermo-resistance
Range: Same as Output
Function |
Part No.VC14
Add
to cart
|
| TC-920
Thermocouple / Thermometer / Calibrator
2 in 1 meter …thermocouple thermometer and
temperature calibrator
- Fahrenheit/Celsius
selectable for temperature
measurement and calibration
- Large
LCD display
- Data
hold
- RS232 PC
serial computer interface
- Battery
included
SPECIFICATIONS:
Temperature Range: -325 to 2246°F/-199
to 1230°C Power Supply: Single
9V battery Dimensions: 7.3 x 3.1
x 1.5" (185 x 78 x 38mm)
Weight: 9.9 oz (280g)
Part No.TC-920
Add
to cart 
Part No.SW-U801-WIN
Add
to cart 
Part No.UPCB-02
Add
to cart 
Part No.CA-05A
Add
to cart 
For
prices, click item "Add to
Cart" icon or call 888-849-8034
|
BX-500
Infrared Temperature Calibrator
Portable infrared temperature calibrator is as easy to use as point and shoot.
- Wide
field of view to compensate for
optical variations in individual
infrared thermometers
- Fixed
emissivity of 0.95
- Simply
set the desired temperature in
increments of 0.1¡ã, wait for
the calibrator to attain
equilibrium, point the infrared
thermometer at the target, and
measure the radiated energy
- Contact
RTD reference well is located
directly behind the blackbody
target to assure even higher
accuracies of ±0.1ºC
SPECIFICATIONS:
Temperature Range: 50 to 500ºC
(122 to 932ºF)
Resolution: 0.1ºC (0.1ºF)
Accuracy: ±0.8ºC (±1.6ºF):
≤100ºC (212ºF); ±1.6ºC
(±3.2ºF): 100 to ≤200ºC
(212 to 392ºF); ±2.8ºC (±5.6ºF):
200 to ≤500ºC (392 to
≤932ºF)
Stability: ±0.1ºC (±0.2ºF):
≤100ºC (212ºF); ±0.2ºC
(±0.4ºF): 100 to ≤350ºC
(212 to 662ºF); ±0.4ºC (±0.8ºF):
350 to ≤500ºC (662 to
≤932ºF)
Target Emissivity: Fixed at 0.95
Cooling Time: 45 minutes to 100ºC
(122ºF)
Heating Time: 40 minutes to
maximum
Aperture Diameter: 57mm
Power Supply: 220VAC (±10%),
1.25A/110VAC (±10%), 2.5A
Dimensions: 180 x 114 x 233mm
Weight: 3 kg
Part No.BX-500
Add
to cart
|
Many
more models are available. Contact INDUSTRY DEPOT with your